Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 43
Filter
2.
Dig Liver Dis ; 2023 Dec 16.
Article in English | MEDLINE | ID: mdl-38105148

ABSTRACT

The implementation of FIT programs reduces incidence and mortality from CRC in the screened subjects. The ultimate efficacy for CRC morbidity and mortality prevention in a FIT program depends on the colonoscopy in FIT+ subjects that has the task of detecting and removing these advanced lesions. Recently, there has been growing evidence on factors that influence the quality of colonoscopy specifically withing organized FIT programs, prompting to dedicated interventions in order to maximize the benefit/harm ratio of post-FIT colonoscopy. This document focuses on the diagnostic phase of colonoscopy, providing indications on how to standardise colonoscopy in FIT+ subjects, regarding timing of examination, management of antithrombotic therapy, bowel preparation, competence and sedation.

3.
Endoscopy ; 55(3): 225-234, 2023 03.
Article in English | MEDLINE | ID: mdl-35915956

ABSTRACT

BACKGROUND : It is unknown whether there is an advantage to using the wet-suction or slow-pull technique during endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) with new-generation needles. We aimed to compare the performance of each technique in EUS-FNB. METHODS: This was a multicenter, randomized, single-blind, crossover trial including patients with solid lesions of ≥ 1 cm. Four needle passes with 22 G fork-tip or Franseen-type needles were performed, alternating the wet-suction and slow-pull techniques in a randomized order. The primary outcome was the histological yield (samples containing an intact piece of tissue of at least 550 µm). Secondary end points were sample quality (tissue integrity and blood contamination), diagnostic accuracy, and adequate tumor fraction. RESULTS: Overall, 210 patients with 146 pancreatic and 64 nonpancreatic lesions were analyzed. A tissue core was retrieved in 150 (71.4 %) and 129 (61.4 %) cases using the wet-suction and the slow-pull techniques, respectively (P = 0.03). The mean tissue integrity score was higher using wet suction (P = 0.02), as was the blood contamination of samples (P < 0.001). In the two subgroups of pancreatic and nonpancreatic lesions, tissue core rate and tissue integrity score were not statistically different using the two techniques, but blood contamination was higher with wet suction. Diagnostic accuracy and tumor fraction did not differ between the two techniques. CONCLUSION: Overall, the wet-suction technique in EUS-FNB resulted in a higher tissue core procurement rate compared with the slow-pull method. Diagnostic accuracy and the rate of samples with adequate tumor fraction were similar between the two techniques.


Subject(s)
Pancreatic Neoplasms , Humans , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/pathology , Endoscopic Ultrasound-Guided Fine Needle Aspiration/methods , Suction/methods , Cross-Over Studies , Single-Blind Method , Pancreas/diagnostic imaging , Pancreas/pathology
7.
Surg Endosc ; 36(6): 4553-4569, 2022 06.
Article in English | MEDLINE | ID: mdl-34724586

ABSTRACT

BACKGROUND: EUS-guided biliary drainage (EUS-BD) with Lumen Apposing Metal Stent (LAMS) is a mini-invasive approach for jaundice palliation in distal malignant biliary obstruction (D-MBO) not amenable to ERCP, with good efficacy and not exiguous adverse events. AIMS AND METHODS: From January 2015 to December 2019, we retrospectively enrolled all the EUS-BD with electrocautery-enhanced LAMS for biliary decompression in unresectable D-MBO and failed ERCP. Primary study aims were to evaluate technical/clinical success and AEs rate. In case of maldeployment, we estimated the efficacy of an intra-operative rescue therapy. Secondary aims were to assess the jaundice recurrence and gastric outlet obstruction symptoms. RESULTS: Thirty-six EUS-BD were enrolled over a cohort of 738 patients (ERCP cannulation failure rate was 2.6%): 31 choledocho-duodenostomy and 5 cholecystogastrostomy. A pre-loaded guidewire through the LAMS was systematically used in case of common bile duct ≤ 15 mm or scope instability for a safe/preventive biliary entryway in case of intra-procedural complications. Technical success was 80.6% (29/36 patients). Seven cases of LAMS maldeployment during EUS-guided choledocho-duodenostomy were successfully treated with RT by an over-the-wire fully-covered Self-Expandable Metal Stent (FC-SEMS). The FC-SEMS was released through the novel fistula tract in endoscopic fashion in 5/7 cases and transpapillary in percutaneous-transhepatic-endoscopic rendezvous (1/7) and laparoscopic-endoscopic rendezvous (1/7) in the two remaining cases. The total efficacy of rescue therapy was 100%. Same-session duodenal SEMS was placed in 17 patients with optimal gastric outlet obstruction management. Final clinical success was 100% and no other late adverse events or FC-SEMS migration were observed. CONCLUSION: EUS-BD with LAMS is effective for jaundice palliation after ERCP failure but with considerable adverse events. Maldeployment remains a serious complication with fatal evolution if not correctly recognized/managed. Rescue therapy must be promptly applied especially in tertiary-care centers with highly skilled endoscopists, interventional radiologist and dedicated surgeon.


Subject(s)
Cholestasis , Gastric Outlet Obstruction , Neoplasms , Cholangiopancreatography, Endoscopic Retrograde/adverse effects , Cholestasis/etiology , Cholestasis/surgery , Drainage/adverse effects , Endosonography/adverse effects , Gastric Outlet Obstruction/etiology , Humans , Neoplasms/complications , Retrospective Studies , Stents/adverse effects , Ultrasonography, Interventional/adverse effects
10.
Expert Opin Biol Ther ; 21(8): 1133-1141, 2021 08.
Article in English | MEDLINE | ID: mdl-34042009

ABSTRACT

OBJECTIVE: There is a growing need for biomarkers to predict therapeutic outcome in Crohn's disease (CD). MAIN OUTCOME MEASURES: The aim was to evaluate whether NLR (neutrophil-to-lymphocyte ratio), PLR (platelet-to-lymphocyte ratio), ELR (eosinophil-to-lymphocyte ratio), and ENLR (eosinophil*neutrophil-to-lymphocyte ratio), could be prognostic biomarkers of endoscopic response (ER) when starting biologics. RESEARCH DESIGN AND METHODS: Patients with CD who started biologics were enrolled. Multivariate analysis was used to evaluate whether NLR, PLR, ELR and ENLR at baseline and at w12 could predict ER (Simple Endoscopic Score for Crohn's disease [SES-CD] ≤2 or SES-CD≤2 and Rutgeerts i0-i1) after 52 weeks of treatment. Area under the curve (AUC) was calculated to find the cutoffs. RESULTS: 107 patients were included. Patients who achieved ER had significantly lower baseline NLR (p = 0.025), ELR (p = 0.013), and ENLR (p = 0.020) compared with those without ER; results after 12 weeks of treatment for ELR (p = 0.006) and ENLR (p = 0.003). AUC was 0.64 (p = 0.003), 0.67 (p = 0.006) and 0.65 (p = 0.014) for NLR, ELR and ENLR. CONCLUSIONS: Low NLR, ELR and ENLR can predict ER and could be used in clinical practice for a better management of CD patients.


Subject(s)
Biological Products , Crohn Disease , Biological Products/therapeutic use , Biomarkers , Crohn Disease/diagnosis , Crohn Disease/drug therapy , Humans , Lymphocytes , Neutrophils , Prognosis , Retrospective Studies
19.
Dig Liver Dis ; 52(2): 178-184, 2020 02.
Article in English | MEDLINE | ID: mdl-31601535

ABSTRACT

BACKGROUND: Standard suction and slow-pull techniques have been utilized during endoscopic ultrasound-guided fine needle aspiration of pancreatic solid lesions, but the correct sampling technique remains unclear. New needles designed to obtain samples suitable for histological evaluation have become available. We performed a study comparing the two sampling methods during endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) in patients with pancreatic solid lesions. METHODS: We performed EUS-FNB with a 20 Gauge FNB needle using slow-pull or standard suction techniques in a prospective, randomized, multicenter study. The primary aim was bloodiness of the collected specimens. Secondary aims were technical success and performance of the two techniques. RESULTS: 110 patients were included (55 per group). No difference in blood contamination was observed (slow-pull 80% vs. suction 74%, p = 0.917). Technical success was 95% (96% vs. 94%, p = 0315). Sensitivity (96% vs. 93%), specificity (100% vs. 100%), positive likelihood ratio (NA), negative likelihood ratio (0.04 vs. 0.07), diagnostic accuracy (96 vs. 93%) did not differ between the two groups. CONCLUSION: EUS-FNB with slow-pull and standard suction techniques are comparable in terms of blood contamination providing similar high diagnostic sensitivity and accuracy in pancreatic solid lesions. The use of the new generation FNB needle allows to reach such high level of diagnostic adequacy regardless of the technique utilized.


Subject(s)
Endoscopic Ultrasound-Guided Fine Needle Aspiration/methods , Needles , Pancreatic Neoplasms/pathology , Suction/methods , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Neuroendocrine Tumors/pathology , Prospective Studies , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...